Products

   Contact Us

 

1030 Series Air Gages

 

Air-Electronic

Converter

Air Plug Gage

Air Ring Gage

Air probe

1032.10.1-2-3 1032.10.4-5 1030.10.1-2-3

 

 

Air gauging guarantees high precision and longtime stability of the measurement. Environment conditions have nearly no influence on the excellent precision and repeatability that can be achieved by this method. Non-contact measurement with air avoids damages of the workpieces. Typical applications are measurements of diameters, center distances, tapers, eccentricity, matching of shaft to bore a.s.o.

 

  The measured value is converted into an electronic signal which can be processed by any type of PRETEC measuring instruments. Or indication with dial indicator.

 

  The measuring range of a standard converter is ± .0015" (± 40 µm). Special executions are available up to ± .003 (± 80 µm).

 

Model 1030-1032.10.1 

Standard for jet dia.0.023”   

Standard for jet dia.0.60mm

range ± 0.0015”   

range ± 0.040mm

Model 1030-1032.10.2

Standard for jet dia.0.080” 

Standard for jet dia.2.07mm

range ± 0.0015”  

range ± 0.0015”

Model 1030-1032.10.3

Standard for jet dia.0.080” 

Standard for jet dia.2.07mm

range ± 0.0030”   

range ± 0.080mm

 

 

Principal of Converter function

1  Air pressure regulator

2  Electronic Transducer, Dial or Digital Indicator

3  Pressure Chamber

4  Membrane

5    Air Gage

 

Bore measurement Multiple bore measurement Taper measurement Center distance measurement
Parallelism and perpendicularity measurement Position measurement of a rotating abrasive wheel on a grinding machine Straightness measurement

 

1032.81.X Air Probe

1032.60.X, 1032.61.X, 

1032.62.X, 1032.63.X Air Plug

1032.67.X and 1032.68.X 

Air Ring

Special Air Plugs